Orthopedic Electric Power Tools User Manual
1. Introduction
Welcome to the Jindal Medi Surge (JMS) Orthopedic Electric Power Tools User Manual. This manual is designed to provide essential information for the safe and effective use of our orthopedic electric power tools. Our tools are designed with the highest quality standards to assist healthcare professionals in performing precise orthopedic procedures.
2. Safety Information
2.1 General Safety Guidelines
Always read the entire manual before operating the equipment.
Only trained and qualified personnel should operate this equipment.
Ensure the work area is clean and well-lit.
Keep bystanders, children, and unauthorized persons away from the work area.
Do not use the tool in explosive atmospheres or near flammable substances.
2.2 Personal Protective Equipment (PPE)
Wear appropriate PPE, including gloves, eye protection, and hearing protection.
Ensure that your clothing is fitted and does not have any loose parts that could get caught in moving components.
2.3 Electrical Safety
Verify that the power supply voltage matches the tool's specifications.
Use only grounded outlets and never bypass the grounding pin.
Disconnect the tool from the power supply before making any adjustments, changing accessories, or performing maintenance.
2.4 Tool Safety
Inspect the tool before each use. Do not operate if any parts are damaged or missing.
Use only accessories and attachments recommended by JMS.
Keep hands and body away from moving parts during operation.
Always follow the correct operational procedure for each specific tool.
3. Components Overview
3.1 Main Components
Motor Unit: The core component that drives the tool.
Handpiece: The part of the tool that the operator holds, typically containing the controls.
Battery Pack/Power Cord: Provides the power supply to the tool.
Cutting/Drilling Attachments: Various interchangeable parts used for cutting, drilling, or sawing bone.
3.2 Controls and Indicators
Power Switch: Turns the tool on and off.
Speed Control Dial: Adjusts the speed of the tool.
Trigger: Activates the tool when pressed.
Battery Level Indicator (if applicable): Displays the remaining battery charge.
4. Operating Instructions
4.1 Preparation
Ensure the tool is disconnected from the power source.
Select and install the appropriate attachment for the procedure.
Check that all components are securely fastened.
4.2 Operation
Connect the tool to the power supply or ensure the battery is charged and inserted.
Turn on the tool using the power switch.
Adjust the speed as required using the speed control dial.
Position the tool at the intended site and press the trigger to start the operation.
Guide the tool smoothly and steadily; avoid applying excessive force.
Release the trigger to stop the tool.
4.3 Post-Operation
Turn off the tool and disconnect it from the power supply.
Remove and clean the attachment.
Store the tool in a safe, dry place.
5. Maintenance and Care
5.1 Routine Cleaning
After each use, clean the tool with a soft, dry cloth.
Disinfect all components that come into contact with the patient.
Do not immerse the tool in water or other liquids.
5.2 Lubrication
Lubricate moving parts as specified in the maintenance schedule.
Use only JMS-approved lubricants.
5.3 Battery Care (if applicable)
Charge the battery fully before the first use.
Avoid deep discharging; recharge when the battery level is low.
Store the battery in a cool, dry place when not in use.
6. Troubleshooting
Issue
Tool does not start
Power supply not connected
Check the connection and plug in the tool
Tool stops during operation
Possible Cause
Overload protection activated
Let the tool cool down and restart
Reduced cutting/drilling efficiency
Worn or damaged attachment
Solution
Replace with a new attachment
Excessive vibration
Loose attachment
Tighten the attachment securely
7. Contact Information
Jindal Medi Surge (JMS)
Email: info@jmshealth.com
Website: www.jmshealth.com
Thank you for choosing Jindal Medi Surge (JMS). We are committed to providing you with high-quality tools to support your orthopedic surgical needs.